    A boost button gives the occupant the option to temporarily increase the speed of the fan when high levels of moisture are being produced, for example when cooking or drying clothes indoors.  

    The unit will revert back to its usual settings after two hours, to maintain optimum levels of comfort for the occupants.

    Features & Benefits:

    • Occupant controllability - allows the occupant the ability to set the levels to suit their preferences for their home environment 
    • Wireless control - the PIV unit (DRI-ECO-LINK-HC) is controlled via radio frequency to allow wireless commands from switch to unit
    • Extremely low power consumption - 3v lithium battery (approx 10 year life) is provided with switch
    • Automated technology - the PIV unit receives a signal from the DRI-ECO-2S which intelligently responds to the occupants' individual airflow requirements
    • Easy installation - switch comes with adhesive tape pre-fitted on the back, or the option to screw in to the wall.  Can be fitted anywhere in the home.
    Unit Binding Mode
    Where wireless sensors/switches are present, they must first be bound to the fan unit before it can work. In order to bind to the switches/sensors the fan must be in binding mode. The steps required to enter binding mode are shown below.
    1.Ensure the fan unit is powered on.
    2.Unit will enter the start-up sequence for 2 minutes when first powered on. Press the down button on the ceiling diffuser control panel once, to exit the start-up sequence.
    3.Press and hold both the UP and DOWN buttons for 20 seconds then release, a single horizontal bar on the display flashes.
    4.Press "down" to enter binding mode (binding mode lasts for 5 minutes).
    5.The unit will now display a flashing ‘b’ to indicate it has entered binding mode
    Binding a 2 Way Switch
    Once the fan unit is in binding mode a switch may now be bound.
    • Press and hold the ‘Boost’ button.
    • The LED will flash GREEN twice when bound.
    To check the binding of a switch, press “boost”.
    A green LED denotes that the switch is bound and the fan should run at full speed.
    A red LED denotes that the switch is not bound.
    Note: if “b” and “P” are flashing on the display, the unit is in binding mode and purge (full speed). 